ZOZEN is one of the most influential boiler manufacturers all over the world. The products have been exported to Indonesia, Pakistan, Philippines, Malaysia, Vietnam, Russia, Kazakhstan, Thailand, Australia, Algeria, Outer Mongolia, Papua New Guinea, Bangladesh, Nigeria, Colombia, Tanzania, Mauritius, Madagascar, India, Oman, Laos, Saudi Arabia, Singapore, South Africa and many other countries. ZOZEN’s boilers are used for application in building materials, chemical, pharmaceutical, paper, textile, food, electronics, automobile manufacturing, rubber and many other industries.
Our products sell well all over the world, and have advanced technology in the field of industrial boiler.
Product thermal capacity:1-20 t/h
Working pressure:0.7-2 Mpa
Product thermal capacity: 20-110 t/h
Working pressure: 1.25-5.3 Mpa
Product thermal capacity: 20-75 t/h
Working pressure: 1.25-5.4 MPA
Product thermal capacity: 2 – 20t/h
Working pressure: 1 - 2.5 MPA
Product thermal capacity: 4-35 t/h
Working pressure: 1.0-2.5 MPA
Working pressure: 1.0-1.6 MPA
Outlet temperature: 115/70 ℃
Product thermal capacity: 10 - 75 t/h
Working pressure: 1.25-2.45MPA
Product thermal capacity: 1400-29000 KW
Working pressure: 0.8-1.0 MPA
Product thermal capacity: 7000-29000 KW
Working pressure: 0.8-1.0 MPA
09/02/2016 · The proper way to bottom blowdown a boiler is to start with both valves fully closed. Start by opening the knife valve, then completely open and then close the gate valve. Do this to both front and back drain valves if your boiler is so equipped.
Read More08/11/2016 · Since steam boilers produce steam from water, they require the regular replenishment of feed water. As a result, you can expect the accumulation of impurities of waste by products. The boiler blowdown procedure is an effective way of removing those impurities to ensure your long life and efficiency of your boiler. Continue reading to learn more about the boiler blowdown procedure. Is the …
Read More2019-4-15 · After blow down, open both the steam valve and the water valve and allow 30 minutes for set-up to achieve normal operating temperatures. The feedwater regulator must be blown down whenever the drum pressure has dropped below 25 psi. The act of blowing down removes all air in the system and insures proper operation.
Read MoreBlowdown in Boiler, Usually, water which is fed to the boiler contains high Total Dissolved Solids (TDS) content as well as other dissolved and undissolved solids in it. On heating water or converting water to steam, these dissolved solids do not evaporate and gets separated from water or steam and settled at the bottom of the shell.
Read MoreRelated Topics . Steam and Condensate - Steam & condensate systems- properties, capacities, pipe sizing, systems configuration and more; Related Documents . ASME - International Boiler and Pressure Vessel Code - The International Boiler and Pressure Vessel Code establishes rules of safety governing the design, fabrication, and inspection of boilers and pressure vessels, and nuclear power plant …
Read MoreIn most cases, boiler water blowdown heat recovery systems use flash steam from the flash tank for deaeration. The blowdown from the flash tank is passed through an exchanger and used to preheat boiler makeup water.
Read More23/07/2019 · Boiler blowdown means a certain volume of water is blown off through blowdown valve and is automatically replaced by feed water to maintain the desired level of total dissolved solids (TDS) in the boiler water.
Read More